Online Shop
Lab Gruppen iP 2100 2 x 700W into 4ohms, 1400W into 8ohms bridged. £1,521.37
Description
The iP 2100 is a space-saving power amplifier, ideal for use in installations as well as in cost-effective live sound systems.
The Iron Power (iP) family of power amplifiers is the new compact and versatile line of professional power amplifiers with classic toroidal iron transformers. To achieve a compact design, the latest semiconductor technology is utilized. This, together with Lab.gruppen’s proprietary copper cooling system, Intercooler®, enhances the 2 ohms capacity. A new Bi-phase wiring scheme also increases the capacity of the power supply. This extends the power bandwidth in the low end.
R.R.P. £2,029.75
Our Price: £1,521.37 Inc VAT
Technical Specifications
- MAX OUTPUT POWER 1)
- EIA at 1 kHz and 1% THD FTC 20-20kHz @0.1%THD
- 8 Ω per channel 425 W 400 W
- 4 Ω per channel 700 W 670 W
- 2 Ω per channel 1050 2), 1175 3) W 980 2) W
- 8 Ω bridged 1400 W 1300 W
- 4 Ω bridged 2100 2) W 1900 2) W
- Max output voltage
- 8 ohms load 58 Vrms
- Peak voltage, no load 92 V
- Distortion etc.
- THD 20Hz-20kHz and 1W to full power 0,05 %
- THD @ 1kHZ and –1dB under clip 0,005 %
- DIM 30 at –3dB under clip 0,005 %
- Hum and Noise <-110 dB
- Channel separation @10kHz 70 dB
- Output impedance 30 mΩ
- Slew Rate 45 V/µs
- Inputs
- Gain, selectable [dB] 20, 23, 26, 29
- 32, 35, 38, 41
- Impedance 20 kohm
- Common mode rejection 50 dB
- Front Panel
- Gain controls (2) channel A, B 31 pos detent
- Protect indicator (2) yellow LEDs 80°C at heatsink or <12kHz at full power or shorted output
- Clip Indicator (2) red LEDs Fast peak - slow release
- Signal present indicator (2) green LED’s -40dB below full output
- On Indicator (2) green LEDs DC rail voltage for channel A and B
- Rear Panel
- Input connectors (2) Neutrik Combo XLR type, 3 pin & 1/4” jack
- Input / Link connectors (2)3-pin Phoenix terminal block
- Output connectors (4) Neutrik 4-pole Speakon connectors
- Switches
- Clip limiter A and B On-Off (switchable)
- MLS switch 0, -3 dB
- Link-switch Ch.A-B
- Power 230 V version 115 V version
- Operation voltage 130 V-265 V AC 65 V – 135 V AC
- Minimum start voltage 190 V 95 V AC
- Full output power at 4ohms 230 V AC 115 V AC
- Peak inrush current (Soft start limited) 20 A 10 A
- Current Draw @ 4ohms & 230V
- Quiescent power (no load) 0.8 Arms 1.6 Arms
- 1/8 of full power (-9dB) 5 Arms 10 Arms
- 1/3 of full power (-5dB) 8 Arms 16 Arms
- At full power (0 dB) @1 kHz 1% THD 13 Arms 26 Arms
- Net Dimensions mm (inch) 483 (19”) W x 88 (3,5”) H x 325 (12,8”) D
- Shipping Dimensions mm (inch) 560 (22”) W x 180 (7.1”) H x 500 (19.7”) D
- Net Weight 18 kg (39.6 lbs)
- Shipping Weight 19.6 kg (43 lbs)
- Approvals CE Emission EN 55 103-1, E3
- Immunity EN 55 103-2, E3, with S/N below 1% at normal operation level
- Safety EN 60 065, class I
- THX iP2100T
Features
- 2 x 425 watts @ 8 Ω
- 2 x 700 watts @ 4 Ω
- 2 x 1050 watts @ 2 Ω
- (Measured just below clip level, with both channels driven)
- Compact design: 2U high
- Intercooler® cooling system with front-to-rear airflow
- Multiple positions gain switch
- Easily accessible dust filter
- Improved low-end power bandwidth
- Neutrik Combo jack and Phoenix terminal block input connectors
- Bridged mono outputs in one SpeakOn connector
- Besides the traditionally superb Lab.gruppen sonic performance, there is a full line of features to make the iP family functional in all situations from installation to cost-effective live sound systems:
- Multiple positions Gain switch
- To meet the demands for a flexible gain structure in the system, Lab.gruppen offers a multiple position gain switch. The maximum amplifier gain can be set to all industry standards: 20, 23, 26, 29, 32, 35, 38 and 41 dB.
- Versatile input connection
- With the Neutrik Combo-jack we offer both the professional XLR-type standard and the semi-pro 1/4” TRS phono-jacks. For installations the 3-pin Phoenix terminal block may be handier.
- Soft Start
- Toroidal transformers require a huge amount of start current to build up a magnetic flux when the amplifier is switched on. Therefore Lab.gruppen have included a soft start circuit to minimize the risk of blowing the wall fuse and to reduce flickering in the lighting.
- Sophisticated protection circuitry, combining:
- - ALStm short circuit protection; the Adaptive Limiting System permits very high peak currents, but keeps the amplifier within the Safe Operation Area.
- - DC protection; protects against infrasonic signals
- - VHF protection; protects the loudspeakers against strong very high frequency non-musical signals above the audible range.
- - Thermal protection; prevents the amplifier from being overheated. The protection indicators on the front panel are switched on, as a warning, before the protection process is initiated.
- - AC protection; shuts down the power supply if the line voltage is outside the operating voltage.
- - Clip limiter; prevents severely clipped waveforms from reaching the loudspeakers, whilst maintaining full peak power.